Solar Calculator Canada

Solar Power Calculator for Foam Lake, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Foam Lake
  • GPS Coordinates: 51.6410806, -103.53955
  • Elevation: 556 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Foam Lake: 43o
  • Average yearly irradiance: 1516.78 kWh/m2
  • Average yearly power output: 129936 kWh
Sun Path Foam Lake

Average yearly irradiance delivered by the Sun in Foam Lake is 1516.78/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 129936 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.84 56.99
February 2.82 78.91
March 3.54 109.8
April 5.37 161.2
May 5.83 180.6
June 5.73 171.87
July 6.21 192.38
August 5.88 182.34
September 5.01 150.22
October 3.76 116.7
November 2.19 65.72
December 1.61 50.06
Total yearly 1516.78

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 178.45 5531.91
February 270.11 7562.98
March 321.01 9951.36
April 465.01 13950.4
May 487.8 15122
June 467.31 14019.4
July 499.77 15492.7
August 476.81 14781.1
September 418.12 12543.6
October 328.43 10181.3
November 200.74 6022.23
December 154.09 4776.87
Total yearly 129936

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Foam Lake solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 109.69 3400.49
February 190.87 5344.26
March 266.81 8271.02
April 441.02 13230.7
May 509.72 15801.4
June 507.23 15216.8
July 531.57 16478.6
August 469.77 14562.9
September 364.3 10929.1
October 246.9 7653.97
November 130.86 3925.85
December 90.98 2820.47
Total yearly 117636

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 124.87 3870.95
February 209.01 5852.26
March 280.78 8704.22
April 451.42 13542.6
May 512.13 15876.1
June 505.83 15174.8
July 532.5 16507.5
August 477.13 14791.1
September 379.72 11391.5
October 266.22 8252.78
November 146.47 4394.24
December 104.87 3250.91
Total yearly 121609

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 138.76 4301.41
February 225.38 6310.71
March 292.83 9077.59
April 459.19 13775.8
May 511.91 15869.2
June 502.18 15065.5
July 530.25 16437.9
August 481.79 14935.5
September 392.66 11779.8
October 283.5 8788.49
November 160.73 4821.94
December 117.62 3646.23
Total yearly 124810

Foam Lake Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 151.32 4691.04
February 239.95 6718.7
March 302.91 9390.31
April 464.32 13929.5
May 508.79 15772.5
June 495.58 14867.5
July 525.01 16275.5
August 483.74 14995.8
September 403.09 12092.6
October 298.69 9259.44
November 173.59 5207.64
December 129.21 4005.41
Total yearly 127206

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -2.16% temperature and irradiance loss. This totals to about -14.33%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Saint-Donat-de-MontcalmSaint-OdilonSaint-Barnab�-NordSaint-Camille-de-BellechasseSaint-�douardProulxvilleTee LakeSaint-Cyrille-de-L'IsletL'Islet-sur-MerFabreHavre-AubertPetite-Rivi�reLes �troitsSaint-Bernard-sur-MerSullyEstcourtGuiguesSaint-Fid�leSaint-AntoninSquatecPointe-�-la-GardeLac-HumquiLes Hauteurs-de-RimouskiRivi�re-PortneufL'AscensionMurdochville